Angelor (Jiangsu) Intelligent Electric co.,LTD.

Position:首页 > Products > Medium-voltage cable accessories catalogue

Medium-voltage inner come plug-in termination

Product Descriptions
  • Premolded stress cone with geometric design and combine with sufficient interface pressure ensures effective electric field control and long-term reliability;

  • With sufficient electrical margin;

  • No heating or filling required;

  • Can be energized immediately after installation.

Contact us

Product Details

Application

• For cable-GIS gas compartment connection.


Compatible Cables

• Cable Type: XLPE or other polymer-insulated, single or three cores copper/aluminum conductor MV power cables;

• Metallic Screen: Steel tape, Copper tape, Copper wires, Al wires, Al foil tape and etc.


Product Application Standards

• Applicable standards: IEC 60502-4,GB/T 12706.4; 

• Interface standard :EN50180 - EN50181.


Technical Parameters

ItemTechnical Specifications

Voltage Level(kV)

12/20 (24) kV

18/30 (36) kV

26/35 (40.5) kV

Rated Voltage (U₀ / U)

12/20 kV

18/30 kV

26/35kV

Highest System Voltage (Uₘ)

24 kV

36 kV

40.5 kV

Partial Discharge Test (pC)

At 1.73 U₀: no detectable PD above specified sensitivity

Power Frequency Withstand Voltage (KV)

At 4.5 U₀ for 5 min, no breakdown or flashover

Lightning Impulse Level(KV)

125

170

200

Pollution Level

Height( mm)

350

Net Weight (Excluding Cable) ( kg)

~3.0

~3.3

~3.5

 

Optional Solutions
• The connection between the cable lug and the cable conductor employs crimping or mechanical methods; 

• The length of the grounding wire can be customized.


Operating Conditions
• Ambient Temperature: -45°C to 45°C

• Indoor,Ring main unit,Pad-mounted transformer.


Storage Conditions
• Optimal Storage Temperature: 10°C to 25°C
• Indoor with dry and clean environment, keep sealing and avoid ≥4 layers overlap.

Aailable Termination Selection (Recommended by Cable Insulation Diameter)

Voltage Level(kV)

Product Type(Single core)

Product Type(Three-core)

Conductor Size Range(mm²)

Cable Insulation Diameter(mm)

12/20/24

CBT20-3 1×70~95

CBT20-3 3×70~95

70~95

21.5~25

12/20/24

CBT20-3 1×120~185

CBT20-3 3×120~185

120~185

25~29

12/20/24

CBT20-3 1×240

CBT20-3 3×240

240

29~32

12/20/24

CBT20-3 1×300

CBT20-3 3×300

300

31.5~34.5

12/20/24

CBT20-3 1×400

CBT20-3 3×400

400

34~37

12/20/24

CBT20-3 1×500

CBT20-3 3×500

500

37~40

12/20/24

CBT20-3 1×630

CBT20-3 3×630

630

42~45

12/20/24

CBT20-3 1×800

CBT20-3 3×800

800

45~48

18/30/36

CBT30-3 1×25~35

CBT30-3 3×25~35

25~35

21.5~25

18/30/36

CBT30-3 1×50~70

CBT30-3 3×50~70

50~70

25~29

18/30/36

CBT30-3 1×95~120

CBT30-3 3×95~120

95~120

29~32

18/30/36

CBT30-3 1×150~185

CBT30-3 3×150~185

150~185

31.5~34.5

18/30/36

CBT30-3 1×240

CBT30-3 3×240

240

34~37

18/30/36

CBT30-3 1×300

CBT30-3 3×300

300

37~40

18/30/36

CBT30-3 1×400

CBT30-3 3×400

400

39~42

18/30/36

CBT30-3 1×500

CBT30-3 3×500

500

42~45

18/30/36

CBT30-3 1×630

CBT30-3 3×630

630

45~48

18/30/36

CBT30-3 1×800

CBT30-3 3×800

800

51~54

26/35/42

CBT35-3 1×25

CBT35-3 3×25

25

25~29

26/35/42

CBT35-3 1×35~50

CBT35-3 3×35~50

35~50

29~32

26/35/42

CBT35-3 1×70~95

CBT35-3 3×70~95

70~95

31.5~34.5

26/35/42

CBT35-3 1×120

CBT35-3 3×120

120

34~37

26/35/42

CBT35-3 1×150~185

CBT35-3 3×150~185

150~185

37~40

26/35/42

CBT35-3 1×240

CBT35-3 3×240

240

39~42

26/35/42

CBT35-3 1×300

CBT35-3 3×300

300

42~45

26/35/42

CBT35-3 1×400

CBT35-3 3×400

400

45~48

26/35/42

CBT35-3 1×500

CBT35-3 3×500

500

48~51

26/35/42

CBT35-3 1×630

CBT35-3 3×630

630

51~54

Note:If the Termination’s specification is outside the above ranges can be customized based on cable section and insulation diameter.