24kV Cold Shrinkable Straight Joint

Product Descriptions
  • The premolded stress cone, designed using geometrical electric field control and combine with sufficient interface pressure, ensures uniform electric field distribution and long-term reliable operation;

  • With sufficient electrical margin;

  • Have excellent sealing performance with armor tape as normal;

  • Mature design with long-term successful service experience.

Contact us

Product Details

Application

• Designed for the connection of MV power cables;

• Suitable for underground tunnels, direct burial installations (protective box recommended), and installation on cable racks or supports;

• Applicable for connecting different cable cross-sections within a certain range of MV cable systems.


Compatible Cables

• Cable type: XLPE or other polymer-insulated, single or three cores MV power cables; 

• Metallic Screen: Copper tape, Copper wires, Al wires, Al foil tape and etc

 

Product Application Standards

Applicable standards: IEC 60502-4,GB/T 12706.4.


Technical Parameters

ItemTechnical Specifications

Voltage Level(kV)

12/20 (24) kV

Rated Voltage (U₀ / U)

12/20kV

Highest System Voltage (Uₘ)

24 kV

Partial Discharge Test (pC)

At 1.73 U₀: no detectable PD above the specified sensitivity

Power Frequency Withstand Voltage (KV)

At 4.5 U₀ for 5 min, no breakdown or flashover

Lightning Impulse Withstand Voltage

125

Overall Dimensions (L × Ø)

420*51

Net Weight (excluding cable)

10

 

Optional Solutions

• The connector between cable conductors could be crimp or mechanical type;

• Optional protective box according to installation conditions; 

• Sectionalized Joint design can be used for longer circuit with outer earthing system.


Operating Conditions

• Ambient temperature: –45 °C to +45 °C

• Installation altitude: No limitation


Storage Conditions

• Optimal Storage Temperature: 10°C to 25°C
• Indoor with dry and clean environment, keep sealing and avoiding ≥4 layers overlap.

Available Straight Joint Selection (Recommended selection based on cable insulation diameter)

Voltage Level (kV)

Product Type

Conductor   Size Range (mm²)

Cable   Insulation Diameter (mm)

Protective   Housing

8.7/15/17.5

JLS- 8.7/15-1x25~50

25~50

16.4~18.5

W/O protective housing

8.7/15/17.5

JLS- 8.7/15-1x70~120

70~120

20.2~23.2

8.7/15/17.5

JLS- 8.7/15-1x150~240

150~240

24.8~28.8

8.7/15/17.5

JLS- 8.7/15-1x300~400

300~400

30.8~34

8.7/15/17.5

JLS- 8.7/15-1x500~630

500~630

36.8~40.2

8.7/15/17.5

JLS- 8.7/15-3x25~50

25~50

16.4~18.5

8.7/15/17.5

JLS- 8.7/15-3x70~120

70~120

20.2~23.2

8.7/15/17.5

JLS- 8.7/15-3x150~240

150~240

24.8~28.8

8.7/15/17.5

JLS- 8.7/15-3x300~400

300~400

30.8~34

8.7/15/17.5

JLS- 8.7/15-3x500~630

500~630

36.8~40.2

Note:It can be customized based on cable section and insulation diameter if the Termination's specification is outside the above ranges .