Angelor (Jiangsu) Intelligent Electric co.,LTD.

Position:首页 > Products > Medium-voltage cable accessories catalogue

40.5kV Cold-Shrinkable Indoor Termination

Product Descriptions
  • Premolded stress cone with geometric design and combine with sufficient interface pressure ensures effective electric field control and long-term reliability;

  • With sufficient electrical margin;

  • Installation requires no specialized tools, heating, or filling;

  • Can be installed vertically, at an inclined (≤30°) position;

  • Can be energized immediately after installation.

Contact us

Product Details

Application

•  Connects cables to overhead lines/copper busbars.


Compatible Cables

• Cable Type:XLPE or other polymer-insulated, Three-cores copper/aluminum conductor MV power cables; 

• Metallic Screen: Steel tape, Copper tape, Copper wires, Al wires, Al foil tape and etc.


Product Application Standards
• Applicable standards: IEC 60502-4,GB/T 12706.4.


Technical Parameters

ItemTechnical Specifications

Voltage Level(kV)

26/35 (40.5) kV

Rated Voltage (U₀ / U)

26/35kV

Highest System Voltage (Uₘ)

40.5 kV

Partial Discharge Test (pC)

At 1.73 U₀: no detectable PD above specified sensitivity

Power Frequency Withstand Voltage (KV)

At 4.5 U₀ for 5 min, no breakdown or flashover

Lightning Impulse Level(KV)

200

Creepage Distance ( mm)

≥1015

Pollution Level

Height( mm)

940

Net Weight (Excluding Cable) ( kg

)

~2.7

 

Optional Solutions
• Creepage distance can be increased accordingly for high-altitude areas; 

• The lug between the cable and terminal could be crimp or mechanical type.


Operating Conditions
• Ambient Temperature: -45°C to 45°C
• Installed indoor or inside electrical cabinet;
• Normal Altitude: ≤ 2000 meters (For higher altitude areas, bigger creepage distance should be selected based on the specific conditions).


Storage Conditions
• Optimal Storage Temperature: 10°C to 25°C
• Indoor with dry and clean environment, keep sealing and avoiding ≥4 layers overlap. 

Available Termination Selection (Recommended by Cable Insulation Diameter)

Voltage Level(kV)

Product Type

Conductor Size Range(mm²)

Cable Insulation Diameter(mm)

26/35/40.5

NLS- 18/30-3x50~120

50~120

30.9~35.6

26/35/40.5

NLS- 18/30-3x150~300     

150~300

37.2~43.2

26/35/40.5

NLS- 18/30-3x400~630     

400~630

46.4~52.6

Note:If the Termination's specification is outside the above ranges can be customized based on cable section and insulation diameter.