Angelor (Jiangsu) Intelligent Electric co.,LTD.

Position:首页 > Products > Medium-voltage cable accessories catalogue

17.5kV T-Connector Front Plug

Product Descriptions
  • Premolded stress cone with geometric design and uniform interfacial pressure from the spring compression system ensures effective electric field control and long-term reliability;

  • Installation requires no specialized tools, heating, or filling;

  • Can be installed vertically, at an incline (≤30°), or inverted;

  • Can be energized immediately after installation.

Contact us

Product Details

Application

• Connects cables to electrical cabinet or transformer.


Compatible Cables

• Cable Type: XLPE or other polymer-insulated, single or three cores copper/aluminum conductor HV power cables; 

• Metallic Screen: Aluminum sheath, lead sheath, copper wire + aluminum-plastic composite tape.


Product Application Standards

Applicable standards: IEC 60502-4,GB/T 12706.4;

Interface standard :EN50180 - EN50181.


Technical Parameters

ItemTechnical Specifications

Voltage Level(kV)

8.7/15 (17.5) kV

Rated Voltage (U₀ / U)

8.7/15kV

Highest System Voltage (Uₘ)

17.5 kV

Partial Discharge Test (pC)

At 1.73 U₀: no detectable PD above specified sensitivity

Power Frequency Withstand Voltage (KV)

At 4.5 U₀ for 5 min, no breakdown or flashover

Lightning Impulse Level(KV)

95

Pollution Level

Height( mm)

250

Net Weight (Excluding Cable)(kg)

~2.5

 

Optional Solutions
• The connection between the cable lug and the cable conductor employs crimping or mechanical methods;

• The length of the grounding wire can be customized


Operating Conditions
• Ambient Temperature: -45°C to 45°C

• Installation altitude: no limitation.


Storage Conditions
• Optimal Storage Temperature: 10°C to 25°C
• Indoor with dry and clean environment, keepsealing and avoiding >=4 layers overlap.

Available Termination Selection (Recommended by Cable Insulation Diameter)

Voltage Level(kV)

Product Type

Conductor Size Range(mm²)

Cable Insulation Diameter(mm)

12/20/24

CBQ10-C-12/20-1x25~35

25~35

16~20

12/20/24

CBQ10-C-12/20-1x50~95

50~95

19.5~24.5

12/20/24

CBQ10-C-12/20-1x120~185

120~185

24~30.5

12/20/24

CBQ10-C-12/20-1x240~300

240~300

30~36

12/20/24

CBQ10-C-12/20-1x400~500

400~500

35.5~42

12/20/24

CBQ10-C-12/20-3x25~35

25~35

16~20

12/20/24

CBQ10-C-12/20-3x50~95

50~95

19.5~24.5

12/20/24

CBQ10-C-12/20-3x120~185

120~185

24~30.5

12/20/24

CBQ10-C-12/20-3x240~300

240~300

30~36

12/20/24

CBQ10-C-12/20-3x400~500

400~500

35.5~42

Note:If the Termination's specification is outside the above ranges can be customized based on cable section and insulation diameter.

Product Recommendation

Copyright © 2026 Angelor (Jiangsu) Intelligent Electric co.,LTD.

Privacy Policy