Angelor (Jiangsu) Intelligent Electric co.,LTD.

Position:首页 > Products > ​High-voltage cable accessories catalogue

550kV Premolded Straight Joint

Product Descriptions
  • Designed for the connection of high-voltage power cables;

  • Suitable for various installation conditions, including underground tunnels, direct burial installations (protective FRP box recommended), and installation on cable racks or supports;

  • Applicable for cross-bonding earthing, protective earthing, or direct earthing in long-distance HV cable systems.

Contact us

Product Details

Compatible Cables

• Cable Type: XLPE or other polymer-insulated, single-core copper/aluminum conductor HV power cables; 

• Metallic Screen: Aluminum sheath, lead sheath, copper wire + aluminium copolymer tape, etc.


Key Features

• The premolded stress cone, designed using geometrical electric field control and combined with sufficient interface pressure, ensures uniform electric field distribution and long-term reliable operation; 

• Sufficient electrical safety design; Heat-shrink tube combined with plumbing provides excellent sealing performance and environmental protection; 

• External grounding outlet design allows easy grounding connection and reliable sealing protection;

• Proven and mature design with extensive successful service experience.


Product Applicable Standards

Applicable standards: IEC 62067, GB/T 22078.


Technical Parameters

Item

Technical Specifications

Rated Voltage (U₀ / U)

290/500 (550) kV

Highest System Voltage (Uₘ)

550 kV

Partial Discharge Test /pCAt 1.5 U₀: no detectable PD above the specified sensitivity

Power Frequency Withstand Voltage /kV

At 2.0 U0 for 30 min, no breakdown or flashover

Lightning Impulse Level /kV

1550KV

Overall Dimensions (L × Ø) /mm

2200*540mm, (with coffin box: 3000*658mm)

Net Weight (Excluding Cable) / kg

160kg (with coffin: 480kg)

 

Optional Solutions

• Conductor onnection between cables by crimping or mechanical connector.

• Optional protective PRF box according to the site requirement.

• Optional fiber optic outlet design.

• Different cable sections connection can be matched according to the sleeve’s using range.


Operating Conditions

• Ambient temperature: –55 °C to +45 °C

• Installation altitude: No limitation


Storage Conditions

• Recommended storage temperature: 10–25 °C

• Storage environment: Indoor, sealed, clean, dry, and protected from heavy load. 

Straight-Through Joint Selection Guide(Recommended selection based on cable insulation diameter)

Voltage Level(kV)

Product   Type

Conductor   Size Range (mm²)

Cable   Insulation Diameter (mm)

Protective   Housing

290/500/550

YJJTI0   290/500

800~2500

100~135

Copper/ AL case

290/500/550

YJJTI1   290/500

800~2500

100~135

Copper/AL case + FRP protection box+ sealing compound

290/500/550

YJJTI2   290/500 

800~2500

100~135

Copper /AL box+sealing compound

Note:If the Termination’s specification is outside the above ranges can be customized based on cable section and insulation diameter.

Product Recommendation

Copyright © 2026 Angelor (Jiangsu) Intelligent Electric co.,LTD.

Privacy Policy