17.5kV Cold-Shrinkable Straight Joint

Product Descriptions
  • The premolded stress cone, designed using geometrical electric field control and combine with sufficient interface pressure, ensures uniform electric field distribution and long-term reliable operation;

  • With sufficient electrical margin;

  • Have excellent sealing performance with armor tape as normal;

  • Mature design with long-term successful service experience.

Contact us

Product Details

Application

• Designed for the connection of MV power cables; 

• Suitable for underground tunnels, direct burial installations (protective box recommended), and installation on cable racks or supports; 

• Applicable for connecting different cable cross-sections within a certain range of MV cable systems.


Compatible Cables

• Cable type: XLPE or other polymer-insulated, single or three cores MV power cables;

• Metallic Screen: Copper tape, Copper wires, Al wires, Al foil tape and etc.,


Product Application Standards

Applicable standards: IEC 60502-4,GB/T 12706.4.


Technical Data

Item Technical Specifications

Voltage Level(kV)

8.7/15 (17.5) kV

Rated Voltage (U₀ / U)

8.7/15kV

Highest System Voltage (Uₘ)

17.5 kV

Partial Discharge Test (pC)

At 1.73 U₀: no detectable PD above the specified sensitivity

Power Frequency Withstand Voltage (KV)

At 4.5 U₀ for 5 min, no breakdown or flashover

Lightning Impulse Withstand Voltage

95

Overall Dimensions (L × Ø)

420*51

Net Weight (excluding cable)

10

 

Optional Solutions

• The connector between cable conductors could be crimp or mechanical type.

• Optional protective box according to installation conditions.

• Sectionalized Joint design can be used for longer circuit with outer earthing system.


Operating Conditions

• Ambient temperature: –45 °C to +45 °C

• Installation altitude: No limitation.


Storage Conditions

• Optimal Storage Temperature: 10°C to 25°C
• Indoor with dry and clean environment, keep sealing and avoiding ≥4 layers overlap.

Available Straight Joint Selection (Recommended selection based on cable insulation diameter)

Voltage Level(kV)

Product Type

Conductor Size Range (mm²)

Cable   Insulation Diameter (mm)

Protective   Housing

12/20/24

JLS-12/20-1x25~35

25~35

16~20

W/O protective housing

12/20/24

JLS-12/20-1x50~95

50~95

19.5~24.5

12/20/24

JLS-12/20-1x120~185

120~185

24~30.5

12/20/24

JLS-12/20-1x240~300

240~300

30~36

12/20/24

JLS-12/20-1x400~500

400~500

35.5~42

12/20/24

JLS-12/20-3x25~35

25~35

16~20

12/20/24

JLS-12/20-3x50~95

50~95

19.5~24.5

12/20/24

JLS-12/20-3x120~185

120~185

24~30.5

12/20/24

JLS-12/20-3x240~300

240~300

30~36

12/20/24

JLS-12/20-3x400~500

400~500

35.5~42

Note:It can be customized based on cable section and insulation diameter if the Termination's specification is outside the above ranges.