Angelor (Jiangsu) Intelligent Electric co.,LTD.

Position:首页 > Products > ​High-voltage cable accessories catalogue

245kV Dry-type GIS Termination

Product Descriptions
  • Premolded stress cone with geometric design and uniform interfacial pressure from the spring compression system ensures effective electric field control and long-term reliability;

  • Sufficient electrical safety design;

  • Interface dimensions fully comply with the latest IEC and GB standards;

  • Dry-type, fully sealed top design for easy installation and elimination of gas leakage risk.

  • The epoxy insulator (GIS plug-in part) can be pre-installed in the GIS enclosure (with sealing insert or sealing plate) before ship to the site, allowing factory electrical testing together with the GIS equipment;

  • Extension rod design allows flexible configuration between short-type and long-type terminations;

  • Proven design with extensive service experience, ensuring high operational reliability.

Contact us

Product Details

Application
• Connects cables to high-voltage switch gear.


Compatible Cables

• Cable Type: XLPE or other polymer-insulated, single-core copper/aluminum conductor HV power cables.

• Metallic Screen: Aluminum sheath, lead sheath, copper wire + aluminium copolymer tape, etc.

Product Application Standards

Applicable standards: IEC 62067, GB/T 18890, IEC 62271-209, GB/T 22381.


Technical Parameters

ItemTechnical Specifications

Voltage Level(kV)

127/220 (245) kV

Rated Voltage (U₀ / U)

127/220kV

Highest System Voltage (Uₘ)

245 kV

Partial Discharge Test /pC

At 1.5 U0 : no detectable PD above specified sensitivity

Power Frequency Withstand Voltage /kV

At 2.0 U0 for 30 min, no breakdown or flashover

Lightning Impulse Level /kV

1050

Overall Height L5/mm

620/960

Net Weight (Excluding Cable) / kg

240

 

Optional Solutions

• End bell to Metallic Sheath Connection: plumbing or mechanic connection.

• Connection between top connector and cable conductor by crimping or mechanical connector.

• Plug-in type or assembly type termination available, supporting multi-angle installation.

• Optional flange surge arrester can be choosed (with L shape copper link)

• Optional fiber optic outlet design.


Operating Conditions

• Ambient temperature: ‒55 °C to +45 °C;

• Installation: Indoor or outdoor substations, connected to GIS equipment

• Installation altitude: No limitation


Storage Conditions

• Recommended storage temperature: 10–25 °C

• Storage Environment: Indoor, sealed, Clean, dry, and protected from heavy pressure.

 

Available Termination Selection (Recommended by Cable Insulation Diameter)

Voltage Level(kV)

Product Type

Standard (L5) (mm)

Conductor Size Range(mm²)

Cable Insulation Diameter(mm)

127/220/245

YJZGGS 127/220  

620

240~2500

81.5~114.5

127/220/245

YJZGGL 127/220

960

240~2500

81.5~114.5

Note:If the Termination’s specification is outside the above ranges can be customized based on cable section and insulation diameter.


Product typial dimension

Conductor Size Range(mm²)

L5[mm]

t2[mm]

M1xt1


LongShort

240 ~ 2500 (Cu/Al)

960

620

475

M12x∅110


Product Recommendation

Copyright © 2026 Angelor (Jiangsu) Intelligent Electric co.,LTD.

Privacy Policy