Angelor (Jiangsu) Intelligent Electric co.,LTD.

Position:首页 > Products > Medium-voltage cable accessories catalogue

36kV Cold-Shrinkable Outdoor Termination

Product Descriptions
  • Premolded stress cone with geometric design and uniform interfacial pressure from the spring compression system ensures effective electric field control and long-term reliability.

  • With sufficient electrical margin.

  • Installation requires no specialized tools, heating, or filling.

  • Can be installed vertically, at an inclined (≤30°) position.

  • Can be energized immediately after installation.

Contact us

Product Details

Application

•  Connects cables to overhead lines/copper busbars.


Compatible Cables

• Cable Type: XLPE or other polymer-insulated, single-core copper/aluminum conductor MV power cables;

• Metallic Screen: Copper tape, Copper wires, Al wires, Al foil tape and etc.    


Product Application Standards
Applicable standards: IEC 60502-4,GB/T 12706.4.


Technical Parameters

ItemTechnical Specifications

Voltage Level(kV)

18/30 (36) kV

Rated Voltage (U₀ / U)

18/30kV

Highest System Voltage (Uₘ)

36kV

Partial Discharge Test (pC)

At 1.73 U₀: no detectable PD above specified sensitivity

Power Frequency Withstand Voltage (KV)

At 4.5 U₀ for 5 min, no breakdown or flashover

Lightning Impulse Level(KV)

170

Creepage Distance ( mm)

≥1260

Pollution Level

Height( mm)

1010

Net Weight (Excluding Cable) ( kg)

~3.7

 

Optional Solutions
• Products with increased creepage distance for high-altitude areas;

• The connection between the cable lug and the cable conductor employs crimping or mechanical methods.


Operating Conditions
• Ambient Temperature: -45°C to 45°C
• Installed on outdoor platforms or vertical towers, and so on;

• Installation altitude: ≤ 2000 meters (For higher altitude areas, products with increased creepage distance should be selected based on specific conditions).


Storage Conditions
• Optimal Storage Temperature: 10°C to 25°C
• Indoor with dry and clean environment, keep sealing and avoiding ≥4 layers overlap.

Available Termination Selection (Recommended by Cable Insulation Diameter)

Voltage Level(kV)

Product Type

Conductor Size Range(mm²)

Cable Insulation Diameter(mm)

18/30/36

WLS- 18/30-1x50~120

50~120

30.9~35.6

18/30/36

WLS- 18/30-1x150~300     

150~300

37.2~43.2

18/30/36

WLS- 18/30-1x400~630     

400~630

46.4~52.6

Note:If the Termination’s specification is outside the above ranges can be customized based on cable section and insulation diameter.