Angelor (Jiangsu) Intelligent Electric co.,LTD.

Position:首页 > Products > Medium-voltage cable accessories catalogue

12kV T-Connector Rear Plug

Product Descriptions
  • Premolded stress cone with geometric design and uniform interfacial pressure from the spring compression system ensures effective electric field control and long-term reliability;

  • Installation requires no specialized tools, heating, or filling;

  • Can be installed vertically, at an incline (≤30°), or inverted;

  • Can be energized immediately after installation.

Contact us

Product Details

Application

• Connects cables to electrical cabinet or transformer.


Compatible Cables

• Cable Type: XLPE or other polymer-insulated, single or three cores copper/aluminum conductor HV power cables; 

• Metallic Screen: Aluminum sheath, lead sheath, copper wire + aluminum-plastic composite tape.


Product Application Standards

Applicable standards: IEC 60502-4,GB/T 12706.4; 

Interface standard :EN50180 - EN50181.


Technical Parameters

ItemTechnical Specifications

Voltage Level(kV)

6/10 (12) kV

Rated Voltage (U₀ / U)

6/10 kV

Highest System Voltage (Uₘ)

12kV

Partial Discharge Test (pC)

At 1.73 U₀: no detectable PD above specified sensitivity

Power Frequency Withstand Voltage (KV)

At 4.5 U₀ for 30 min, no breakdown or flashover

Lightning Impulse Level(KV)

75

Pollution Level

Height( mm)

250

Net Weight (Excluding Cable) ( kg)

~2.5


Optional Solutions
• The connection between the cable lug and the cable conductor employs crimping or mechanical methods; 

• The length of the grounding wire can be customized.


Operating Conditions
• Ambient Temperature: -45°C to 45°C

• Installation altitude: no limitation.


Storage Conditions
• Optimal Storage Temperature: 10°C to 25°C
• Indoor with dry and clean environment, keepsealing and avoiding >=4 layers overlap.

Available Termination Selection (Recommended by Cable Insulation Diameter)

Voltage Level(kV)

Product Type

Conductor Size Range(mm²)

Cable Insulation Diameter(mm)

6/10/12

CBH10-C-6/10-1x25~50

25~50

16.4~18.5

6/10/12

CBH10-C-6/10-1x70~120

70~120

20.2~23.2

6/10/12

CBH10-C-6/10-1x150~240

150~240

24.8~28.8

6/10/12

CBH10-C-6/10-1x300~400

300~400

30.8~34

6/10/12

CBH10-C-6/10-1x500~630

500~630

36.8~40.2

6/10/12

CBH10-C-6/10-1x25~50

25~50

16.4~18.5

6/10/12

CBH10-C-6/10-1x70~120

70~120

20.2~23.2

6/10/12

CBH10-C-6/10-1x150~240

150~240

24.8~28.8

6/10/12

CBH10-C-6/10-1x300~400

300~400

30.8~34

6/10/12

CBH10-C-6/10-1x500~630

500~630

36.8~40.2

Note:If the Termination's specification is outside the above ranges can be customized based on cable section and insulation diameter.

Product Recommendation

Copyright © 2026 Angelor (Jiangsu) Intelligent Electric co.,LTD.

Privacy Policy